I´ve got some wishes as well...
I would love to see an option to disable the "V1" callout (most airlines have an automatic voice that comes up once passing V1), "Apprchoaching Minimum" and "Minimum" callout by the F/O. Furthermore everytime I say "M/A Alt set" the F/O jumpes into the go around mode and it shows "inital climb" in the info bar.
One flow thingy. The right "R HYD DEM Pump" is always switched on and off first and last. This flow is not correct. (FCOM Note: Right demand pump selector must be placed in the AUTO position
first, pressurizing the right system. Failure to pressurize the right system first will transfer hydraulic fluid from the center system into the right system, causing an overfill (OF).)
Another flow that comes from the real world... after landing flow starts from the bottom to the top, so first the transponder then the flaps etc etc.